Skip to main content
Skip table of contents

CAN Keypads

Keypad Settings

Up to two CAN Keypads can be used on a Razor PDM. The list of supported models are detailed below.

Keypad Settings Configuration

Keypad Model

The model of the CAN Keypad. Changing the model will allow different numbers of buttons to be used e.g. a 5 button keypad will let you choose the function on buttons 1 - 5

Button

Choose which Keypad Function is used to control each button on the keypad.

Keypad Function

A Keypad Function determines how a button on the CAN keypad behaves.

There are 16 functions in total which can be used entirely on one keypad, or shared across two. Each function can have its label changed to describe its use.

 

Keypad Function Configuration

Max Count

This button counts up once per press and rolls over to 0 at Max Count.

  • For momentary switch mode, set Max Count to 0

  • For toggle switch mode, set Max Count to 1

  • For increment/decrement/count switch mode, set Max Count to greater than 1

Count

Count holds the number of presses

Status

Status is Active only when the button is pressed.

Rollover

Select if the count should rollover once reaching ‘Max Count’ while incrementing or 0 while decrementing

LED Parameter

Parameter that determines which LED state to use for visual feedback.

LED Colour

Sets the button colour/state that is shown when the LED Parameter is equal to a number from 0 to 7.

Reset Expression

Select a parameter, operator and value that, when evaluated as true, reset the Keypad Function Count

Set Expression

Select a parameter, operator and value that, when evaluated as true, increment or decrement the Keypad Function Count. Allows two buttons to increment/decrement a single count.

Set Mode

Determines whether the Set Expression increments or decrements the count.