Note: The channels you can add to G4+ with the below method are all included in the G4X/G5 Extra Mode, G4X/G5 users do not need to follow this guide to access these channels.
A range of further channels can be added for G4+ users, and sent to the Link CAN Gauge using the “User Streams” mode in PC Link.
Set up of the user streams is as follows:
-
Select another spare CAN channel
-
Set Mode to “Transmit User Stream x” (x being the next unused transmit or receive user stream number)
-
Set CAN ID to the ID that is part of the stream file name - for example if you wish to use “GaugeART_CAN_Gauge_Extra_ID50.lcs”, set the ID to 50
-
Set Transmit Rate to 20Hz
-
Set Format to Normal
-
Change to the Streams tab of the CAN Setup window
-
Select Stream x, and then click Load Stream
-
Select “GaugeART_CAN_Gauge_Extra_ID50.lcs”, and click the Open button (find this in the CAN folder of your PC Link install)
-
If you wish to add a further stream, change back to the mode tab, select the next spare CAN channel
-
Repeat steps 1-7 for the “GaugeART_CAN_Gauge_Extra_IDxx.lcs” file, this time using the CAN ID xx
-
Click Apply, and then OK
-
Make sure a Store (F4) is performed
Copies of the .lcs files mentioned in this guide can be downloaded from the download section.
Available in G4+ as User Streams
|
|||
|---|---|---|---|
CAN_Gauge_Extra_G4+_ID50.lcs
|
CAN_Gauge_Extra_G4+_ID51.lcs
|
CAN_Gauge_Extra_G4+_ID52.lcs
|
CAN_Gauge_Extra_G4+_ID54.lcs
|
|
Ethanol Content |
Lambda Target |
AN Temp 3 |
CAN TC 1 |
|
Fuel Temperature |
Lambda Correction 1 |
AN Temp 4 |
CAN TC 2 |
|
Boost Target |
Lambda Correction 2 |
Differential Fuel Press |
CAN TC 3 |
|
Knock Level Global |
Traction Slip |
|
CAN TC 4 |
|
Knock Count Global |
|
|
|